ALLIED-L461 AUTOVENT 3000, COMPLETE, 2 SEC

Save $1,094.40
  • SKU: ALLIED-L461
  • SKU: ALLIED-L461
  • Condition: Brand New 
  • Warranty: 2 Year
  • MPN: L461
  • Est. Delivery: 4 to 5 Weeks
  • Shipping: Calculated at Checkout
  • No batteries needed; pneumatically-powered
  • Impact-resistant case with shock-absorbing bumpers
  • Meets ASTM, ISO, and KKK-1822C standards
  • MPN: L461
  • Est. Delivery Date: Jan 10 to Jan 24
No reviews

Price:
Sale price$3,554.10 Regular price$4,648.50

Shipping calculated at checkout

Stock:
In stock

Description

Features

Allied Healthcare AutoVent 3000 Automatic Transport Ventilator Features

  • Small, compact, and transport ready.
  • Designed to perform in harsh and toxic environments.
  • Assembles quickly with simplified operating instructions printed on the case.
  • Impact-resistant case with shock-absorbing bumpers and recessed control settings.
  • Rate and volume settings independently operated.
  • Easy-to-monitor patient valve assembly and toxic atmosphere valve are able to deliver additional breaths on demand by inspiratory effort of the patient.
  • Operates exclusively on standard 50 psi source gas, eliminating air entrainment and maintaining the integrity of the specified oxygen concentration.
  • Operates at extreme temperatures.
  • No batteries needed; pneumatically-powered.
  • Allows for PEEP attachment.
  • Meets ASTM, ISO, and KKK-1822C standards.

Specifications

Allied Healthcare AutoVent 3000 Automatic Transport Ventilator Specifications

  • Supply Pressure Range: 40 - 60 psig.
  • Gas Consumption Driving Gas: 0.5 lpm maximum.
  • Operating Temperature: 0 to 125 °F.
  • Storage Temperature: -40 to 160 °F.
  • Shipping Weight: 5.75 lb (2.6 kg).
  • Shipping Dimensions: 15" x 12" x 9" (38 cm x 30.5 cm x 23 cm).

Control Module:

  • Weight: 24 oz. (680 grams).
  • Dimensions: 1.75" (D) x 6" (W) x 3.5" (H) (4.4 cm x 15.24 cm x 8.9 cm).
  • Frequency: 8 to 28 BPM.
  • Tidal Volume: 200 to 1200 ml.
  • Flow Rate: 16 to 48 lpm.
  • Inspiratory Time: Approximately 0.75, 1.5, or 2.0 seconds.
  • Expiratory Time: 1.5 to 6.0 seconds.
  • I-E Ratio: 1:1 to 1:4.
  • Case Material: Polyester.
  • Input Connection: Plated brass.
  • Output Connection: Plated brass.
  • Minute Volume: 0 to 24 lpm.
  • Driving Gas: 0.5 lpm maximum.

Patient Valve Assembly:

  • Weight: 16 oz. (450 g).
  • Flow: 0 - 48 lpm at 50 psig (as required in demand mode).
  • Peak Inspiratory Flow: 48 lpm at an airway pressure drop of less than 2.5 cm H2O.
  • Delivery Pressure: 60 +/- 5 cm H2O.
  • (Insp.) Crack Pressure: 0 to -2 cm H2O (0 to -0.8" H2O).
  • Exhalation Resistance:
  • Dead Space: 8 ml (excluding mask).
  • Inlet Fitting: Standard male oxygen DISS.
  • Filter: 25 micron stainless steel mesh.
  • Outlet: 22 mm outside diameter x 15 mm inside diameter (fits standard medical masks, endotracheal tubes, and tracheostomy tubes).
  • Materials: